Deck Footing Size Calculator

Understanding Deck Footings

Critical engineering specifications for deck foundation stability and load distribution.

  • Load Distribution Analysis Point load capacity: 2,000-4,000 lbs/post. Bearing pressure: 1,500-3,000 psf. Load distribution angle: 45-60°. Safety factor: 2.5-3.0. Settlement tolerance: 0.5-1.0".
  • Soil Bearing Capacity Clay: 1,000-2,000 psf. Sand: 2,000-3,000 psf. Gravel: 3,000-4,000 psf. Rock: 4,000+ psf. Compaction requirement: 95% Proctor. Moisture content: 12-18%.
  • Frost Protection Requirements Depth variation: 12-48" by zone. Heave protection: 1.5× frost depth. Seasonal movement: ±0.25". Drainage slope: 2% min. Backfill compaction: 90% min.
  • Structural Design Parameters Concrete strength: 2,500-3,000 psi. Rebar coverage: 3" min. Edge distance: 3" min. Pier-to-footing ratio: 1:2 to 1:3. Bell angle: 30-45° if required.

Engineering Specifications

Excavation Standards

  • Over-dig: 6" each side
  • Bottom level: ±1/4"
  • Side slope: 1:1 max
  • Base prep: 4" gravel
  • Inspection gap: 24hrs

Reinforcement Details

  • Bar size: #4-#5
  • Grid spacing: 12" O.C.
  • Lap splice: 24"
  • Corner bend: 4× dia
  • Chair height: 3"

Drainage Systems

  • Gravel bed: 4-6"
  • Perf pipe: 4" min
  • Slope: 1/8" per foot
  • Filter fabric: 4oz
  • Backfill void: 15%

Post Connections

  • Embed depth: 6-8"
  • Edge distance: 3"
  • Anchor bolt: 1/2-5/8"
  • Base plate: 3/8"
  • Grout pad: 1"

Material Specifications

  • Concrete Requirements Mix design: 3,000 psi min. Air content: 6±1%. Slump: 4-6". W/C ratio: 0.45-0.50. Aggregate size: 3/4-1". Cure time: 7 days min.
  • Steel Reinforcement Grade 60 rebar. Yield strength: 60,000 psi. Tensile strength: 90,000 psi. Elongation: 9% min. Bend test: 3× diameter.
  • Post Anchor Systems Hot-dip galvanized. Thickness: 1/8" min. Uplift capacity: 1,500-2,000 lbs. Lateral load: 750-1,000 lbs. Coating: G185 or better.
  • Waterproofing Materials Membrane thickness: 40 mil. Elongation: 300%. Tensile strength: 1,500 psi. Vapor permeance: 0.1 perms. Chemical resistance: pH 3-11.

Quality Control Measures

  • Testing Requirements Concrete cylinders: 1 set per 50 cy. Slump test: ±1". Air content: ±1.5%. Temperature: 40-90°F placement. Field curing: match structure.
  • Inspection Points Excavation depth: ±2". Base preparation: 95% compaction. Rebar placement: ±1/4". Concrete cover: +1/4", -0". Post alignment: ±1/4" per 10'.
  • Documentation As-built drawings: ±1" accuracy. Material certifications: 100% compliance. Test reports: 24hr submission. Photo documentation: 5 stages min.